Flammability diagram
Plot of flammability in gaseous mixtures
Flammability diagrams show the control of flammability in mixtures of fuel, oxygen and an inert gas, typically nitrogen. Mixtures of the three gasses are usually depicted in a triangular diagram, known as a ternary plot. Such diagrams are available in the speciality literature.[1][2][3] The same information can be depicted in a normal orthogonal diagram, showing only two substances, implicitly using the feature that the sum of all three components is 100 percent. The diagrams below only concerns one fuel; the diagrams can be generalized to mixtures of fuels.
Understanding flammability diagrams
Triangular diagrams are not commonplace. The easiest way to understand them is to briefly go through three basic steps in their construction.
- Consider the first triangular diagram below, which shows all possible mixtures of methane, oxygen and nitrogen. Air is a mixture of about 21 volume percent oxygen, and 79 volume percent inerts (nitrogen). Any mixture of methane and air will therefore lie on the straight line between pure methane and pure air – this is shown as the blue air-line. The upper and lower flammability limits of methane in air are located on this line, as shown.
- The stoichiometric combustion of methane is: CH4 + 2O2 → CO2 + 2H2O. The stoichiometric concentration of methane in oxygen is therefore 1/(1+2), which is 33 percent. Any stoichiometric mixture of methane and oxygen will lie on the straight line between pure nitrogen (and zero percent methane) and 33 percent methane (and 67 percent oxygen) – this is shown as the red stoichiometric line. The upper and lower flammability limits of methane in oxygen are located on the methane axis, as shown.
- The actual envelope defining the flammability zone can only be determined based on experiments. The envelope will pass through the upper and lower flammability limits of methane in oxygen and in air, as shown. The nose of the envelope defines the limiting oxygen concentration (LOC)).
- Triangular diagram showing all possible mixtures of methane, oxygen and nitrogen. Any mixture of methane and air will lie on the blue air-line
- Any stoichiometric mixture of methane and oxygen will lie on the red stoichiometric line
- The actual flammability envelope defining flammable mixtures of methane
See also
- Ternary plot
- Flammability limit
Sources
- Zabetakis, Michael G. (1965). Flammability characteristics of combustible gases and vapors (Buletin 627). US Bureau of Mines, Wash., D.C. p. 129. Archived from the original on May 15, 2012. (His main work, 6.3Mb download)
- Burgess, DS; Furno AL; Kuchta JM; Mura KE (1982). "Flammability of mixed gases". Report of Investigations. RI-8709.
- Mashuga, CV; Crowl DA (1998). "Application of the flammability diagram for evaluation of fire and explosion hazards of flammable vapors". Process Safety Progress. 17 (3): 176–183. doi:10.1002/prs.680170305. S2CID 111043890.
- Crowl, Daniel A. (2003). Understanding Explosions. Wiley-AIChE. ISBN 0-8169-0779-X.
References
- v
- t
- e
Fire protection
- Backdraft
- Boiling liquid expanding vapor explosion (BLEVE)
- Boilover
- Combustibility and flammability
- Conflagration
- Dangerous goods (HAZMAT)
- Deflagration
- Detonation
- Dust explosion
- Enthalpy of vaporization
- Explosive
- Fire class
- Fire control
- Fire loading
- Fire point
- Fire triangle
- Flammability diagram
- Flammability limit
- Flammable liquid
- Flashover
- Flash point
- Friction loss
- Gas leak
- Heat transfer
- Jet fire
- K-factor (fire protection)
- Pool fire
- Pyrolysis
- Spontaneous combustion
- Structure fire
- Thermal radiation
- Water pressure
- Active fire protection
- Automatic fire suppression
- Condensed aerosol fire suppression
- Detonation flame arrester
- External water spray system
- Fire bucket
- Fire prevention
- Fire protection
- Fire retardant
- Fire-retardant fabric
- Fire retardant gel
- Fire-safe polymers
- Fire safety
- Fire sprinkler system
- Fire suppression system
- Firefighting foam
- Flame arrester
- Flame retardant
- Flashback arrestor
- Fusible link
- Gaseous fire suppression
- Hypoxic air technology for fire prevention
- Inerting system
- Intumescent
- Passive fire protection
- Personal protective equipment (PPE)
- Relief valve
- Spark arrestor
- Tank blanketing
- Vehicle fire suppression system
- Annulus (firestop)
- Area of refuge
- Booster pump
- Compartmentalization (fire protection)
- Crash bar
- Electromagnetic door holder
- Electromagnetic lock
- Emergency exit
- Emergency light
- Exit sign
- Fire curtain
- Fire cut
- Fire damper
- Fire door
- Fire escape
- Fire extinguisher
- Fire hose
- Fire hydrant
- Fire pump
- Fire sprinkler
- Firestop
- Firestop pillow
- Firewall (construction)
- Grease duct
- Heat and smoke vent
- Occupancy
- Packing (firestopping)
- Penetrant (mechanical, electrical, or structural)
- Penetration (firestop)
- Pressurisation ductwork
- Safety glass
- Smoke control
- Smoke damper
- Smoke exhaust ductwork
- Smokeproof enclosure
- Standpipe (firefighting)
and services
- Template:Fire
- Template:Firefighting
- Template:HVAC
- Category
- Commons